E.I.C., Ltd., Ecological and Industrial Consulting
 
 

Municipal waste-to-energy plant - Winterthur

EIC Activities
- Flue gas cleaning.
- DENOX-SCNR.
- Extraction of fly ash.
- Environmental impact assessment (EIA).
- Bid specifications, evaluation of offers, contracting (service contracts).
- Supervision of detail engineering, manufacturing, erection and commissioning.
- Supervision of trial operation and guarantee tests.
Technical parameters
Amount of waste: 100 000 t/year
Capacity: 1x12.5 t/h
Net calorific value: 12.5 - 13.8 MJ/kg
Availability: 8000 h/year
Steam parameters: 50 bar/400°C
Energy production: 2.5 MW el /24 MW th, process line
Furnace: Reverse acting grate
Flue gas cleaning: DENOX - SNCR, electrostatic precipitator, wet scrubbing
No. of lines: 2